QIYUE FAN · INDUSTRIAL FAN PRODUCTS

GD30K2-12 Axial Flow Fan

QIYUE FAN GD30K2-12 axial flow fan

Steel Mill Wire Rod Air Cooling Axial Flow Fan

No Information

GD30K2-12 Axial Flow Fan

Belt-driven axial fan for industrial duct ventilation, factory air exchange, process air conveying and equipment-room exhaust.

Designed for pipeline installation with the motor mounted above the casing. Selection is based on airflow, pressure, duct size, blade quantity, blade angle, medium condition and installation layout.

Pipeline Axial Fan for Industrial Air Conveying

The GD30K2-12 axial flow fan is designed to form part of an industrial ventilation pipeline. Air moves through the cylindrical casing along the fan axis, making the series suitable for relatively large airflow, compact straight-through installation and low to moderate system pressure.

The motor is mounted above the fan casing. Power is transmitted through a V-belt arrangement, while the bearing box is positioned inside a protective cylinder. This structure keeps the motor outside the main straight-through air passage under suitable working conditions.

Standard selection is intended for air below 60°C under matching conditions. Corrosive, flammable or harmful gas service requires separate confirmation of gas composition, material, sealing, motor arrangement and electrical safety requirements.

Suitable Conditions and Cases Requiring Special Review

Key Construction Features

Item Configuration Selection Meaning
Fan Size No.6, No.7, No.8, No.9 and No.10 Match required airflow, duct diameter and installation space
Blade Quantity 4 blades or 6 blades Different configurations suit different airflow and pressure points
Blade Angle 15°, 20°, 25° and 30° reference options Blade angle affects airflow, pressure and motor power
Motor Position Motor mounted above the fan casing Keeps the motor outside the main air passage
Bearing Arrangement Bearing box inside the protective cylinder Supports shaft transmission inside the casing structure
Transmission V-belt drive with adjustable motor base Allows belt tension and center-distance adjustment

GD30K2-12 Reference Performance Table

The following four-blade data is retained for preliminary selection. Final performance should be confirmed according to airflow, pressure, blade quantity, blade angle, speed, duct resistance and working medium.

Model Blade Qty. Blade Angle Speed
r/min
Pressure
Pa
Airflow
m³/h
Power
kW
Motor Model
6 4 15–20° 1450 167 7,200–9,500 1.1 Y90S-4
6 4 25–30° 1450 177–185 11,300–13,150 2.2 Y100L1-4
6 4 15–35° 960 74–81 4,800–8,700 0.75 Y90S-6
7 4 15–20° 1450 226 11,500–14,100 2.2 Y100L1-4
7 4 25–30° 1450 235–245 18,000–20,900 4 Y112M-4
7 4 15–30° 960 93–103 7,650–19,900 1.1 Y90L-6
8 4 15–20° 1450 294 17,300–22,000 5.5 Y132S-4
8 4 25–30° 1450 314–324 27,000–31,300 7.5 Y132M-4
8 4 15–20° 960 128 11,400–14,900 1.5 Y100L-6
8 4 25–30° 960 137–145 17,800–20,600 2.2 Y112M-6
9 4 15–20° 960 157 16,200–21,200 2.2 Y112M-6
9 4 25–30° 960 177–183 23,200–29,300 4 Y132M1-6
10 4 15–20° 960 206 22,600–29,700 4 Y132M1-6
10 4 25–30° 960 226–235 35,400–41,000 7.5 Y160M-6

Information Needed Before Quotation

Required Airflow

Send required airflow and operating range.

Pressure or Duct Resistance

Send pressure or main duct resistance.

Duct Size

Confirm duct size and installation space.

Medium Condition

Confirm medium, temperature and special conditions.

Installation Method

Confirm mounting method and airflow direction.

Electrical Requirement

Send voltage, frequency and motor requirement.

Typical Industrial Applications

Duct Ventilation

Installed in ventilation ducts or pipelines.

Factory Air Exchange

For workshop air supply and exhaust.

Process Air Conveying

For process air conveying after review.

Paper Mill Ventilation

For paper-mill ventilation after condition review.

Chemical Plant Ventilation

For chemical ventilation after medium review.

Equipment-Room Cooling

For low-pressure cooling and exhaust.

GD30K2-12 Axial Flow Fan FAQ

What is the GD30K2-12 fan mainly used for?

It is mainly used for industrial duct ventilation, factory air exchange, process air conveying and equipment-room exhaust.

How is it different from a direct-drive axial fan?

The GD30K2-12 uses a belt-drive arrangement with the motor mounted above the casing, while a direct-drive axial fan mounts the impeller directly on the motor shaft.

Can it convey corrosive or flammable gas?

Only after separate review. Gas composition, material, sealing, motor arrangement and safety requirements must be confirmed before selection.

Are six-blade configurations available?

Yes. Four-blade and six-blade configurations are available, but the correct option should be confirmed from the required airflow and pressure point.

What information is needed for quotation?

Please provide airflow, pressure, duct size, medium, temperature, installation method, voltage, frequency, quantity and destination.

Send Your GD30K2-12 Duty Point

Send airflow, pressure, duct size, medium, temperature and installation requirements. QIYUE FAN will review the suitable model, blade configuration and motor.

Hot Tags: gd30k2-12 axial flow fan, China gd30k2-12 axial flow fan manufacturers, suppliers, factory

Send Your Operating Conditions

Airflow, pressure, gas medium, temperature, voltage and quantity.

REQUEST A QUOTE ↗