HOME / PRODUCTS / CENTRIFUGAL FANS / GENERAL-PURPOSE / 4-68
QIYUE FAN · GENERAL-PURPOSE CENTRIFUGAL FANS

4-68 Centrifugal Ventilation Fan

The 4-68 series supports industrial air supply, workshop exhaust, warehouse ventilation and large-building air exchange across a broad selection of fan sizes and drive arrangements. Select from actual airflow, pressure, medium and installation conditions.

QIYUE FAN 4-68 centrifugal ventilation fan — source product photograph
REFERENCE RANGENo.2.8A–20B
DRIVE TYPESA / C / D / B
SPEED RANGE250–2900 r/min
MOTOR RANGE0.55–220 kW
01 · PRODUCT POSITION

Large-Range General Industrial Ventilation

The 4-68 centrifugal fan serves ordinary factory air exchange, general equipment ventilation and supply or exhaust of clean air or non-corrosive gas. The available arrangement depends on fan size, duty point and installation. It is not a universal solution for corrosive, abrasive, explosive or high-temperature service.

Factory and Workshop Air Exchange

Ventilation for production buildings and large workspaces where the selected fan covers actual duct losses.

Warehouse and Large-Building Ventilation

Industrial indoor air exchange and general supply or exhaust, with system resistance reviewed at selection.

Equipment Room Exhaust

Equipment-room ventilation and air replacement under ordinary working-medium conditions.

Existing-Fan Replacement

Match model, operating point, original motor, installation, rotation and outlet orientation instead of replacing only by name.

02 · DRIVE CONFIGURATION

A, C, D and B Transmission Options

The original 4-68 product page identifies four drive directions and their preliminary fan-size grouping. Final manufacturing details and bearings must be verified against the selected model’s catalogue drawing.

A-Type · Direct Drive

Small group, reference 2.8A–5A; compact impeller-on-motor configuration for suitable general ventilation duty.

C-Type · Belt Drive

Medium reference group around sizes 6.3–12.5; supports speed matching and motor positioning.

D-Type · Separate Transmission

Medium reference group around sizes 6.3–12.5; fan shaft, drive components and installation require model-specific review.

B-Type · Large Airflow

Large group, reference 16B–20B. Review installation, foundation, motor and maintenance requirements.

03 · CATALOGUE DATA

4-68 Catalogue Range Summary

The summary below presents the published 4-68 series range. The limits represent the whole series, not a guaranteed operating point for one fan or one speed.

ParameterCatalogue ReferenceSelection Note
Model designation2.8A–20BConfirm exact size and transmission
Drive arrangementA / C / D / BDepends on size, speed and installation
Reference speed250–2900 r/minCompare pressure and airflow at the same operating point
Reference motor rating0.55–220 kWFinal installed motor after engineering review
The series-level range is a starting point. Request the performance curve and size-specific GA and foundation drawing for the selected duty point.
04 · APPLICATION BOUNDARIES

Check the Working Medium Before Using 4-68

Suitable for Project Review

Ordinary clean air, non-corrosive industrial gas and normal building/workshop ventilation when airflow and duct resistance match.

Needs Another Fan or Special Construction

Abrasive particles, significant dust, sticky substances, corrosive chemical gas, high-temperature gas, explosive atmosphere or extreme pressure demand.

Confirm the dust concentration and temperature limits for the selected 4-68 model and working medium before quotation.
05 · TECHNICAL RFQ

What to Send for 4-68 Selection

Provide design airflow, total or static pressure, working-medium composition, normal and maximum temperature, site altitude, electric supply, rotation direction, outlet angle, quantity and installation dimensions. For a replacement, include existing nameplate, motor details, drawings and site photos.

How do 4-68 and 4-72 differ?

Both serve general industrial ventilation, but the current 4-68 source describes a broader 2.8A–20B and A/C/D/B configuration; the current 4-72 source identifies 2.8A–12C and A/C/D. Select from the actual operating point, not only model range.

Can the fan be sized from motor power only?

No. Airflow and pressure must be matched to the same fan-curve operating point and the full system resistance.

Does the reference motor range specify the motor for my project?

No. It is a whole-series reference range. The selected motor must be calculated and confirmed for the final impeller, speed, medium and operating point.

Get a 4-68 Fan Selection

Send the project requirements so we can review the suitable fan size, drive, motor and outlet arrangement.

SEND INDUSTRIAL FAN RFQ →