HOME / PRODUCTS / CENTRIFUGAL FANS / GENERAL-PURPOSE / 4-79
QIYUE FAN · INDUSTRIAL GENERAL VENTILATION

4-79 Centrifugal Ventilation Fan

The 4-79 centrifugal fan supports ordinary indoor air supply, industrial building exhaust, workshop ventilation and large-space air circulation. Confirm airflow, pressure, gas condition and installation before determining model, drive and motor.

QIYUE FAN 4-79 centrifugal ventilation fan — actual product reference
MODEL RANGENo.3A–20E
AIRFLOW RANGE990–226,500 m³/h
TOTAL PRESSURE177–3,334 Pa
STANDARD GAS TEMP.≤80°C
01 · PRODUCT POSITION

General Industrial Supply, Exhaust and Air Exchange

The 4-79 series is suitable for factory buildings, workshops, warehouses, machinery rooms and other large indoor spaces where the supplied or extracted gas is ordinary non-corrosive air. Supply and exhaust layouts have different duct and outlet requirements; the full system resistance must be included in the selection.

Factory Supply and Exhaust

General air supply and extraction where airflow, pressure and duct losses match the selected operating point.

Warehouse and Building Ventilation

Large-space air exchange and circulating airflow under ordinary working-medium conditions.

Machinery-Room Exhaust

General exhaust and heat removal for indoor mechanical and utility rooms.

Replacement Projects

Confirm the old fan duty point, motor, impeller, outlet angle, base dimensions and operating arrangement.

02 · WORKING MEDIUM

Operating Boundaries for Standard 4-79 Duty

ConditionExisting-Page ReferenceEngineering Check
Gas mediumNon-flammable, harmless and non-corrosive ordinary gasConfirm exact gas composition
Sticky substancesNot allowed in the conveyed gasCheck process deposits, condensation and coating risk
Dust and hard particlesNot over 150 mg/m³Special review if dust or wear conditions exceed standard duty
Gas temperatureNot over 80°CReview continuous and peak temperature
These operating-medium boundaries appear consistently across the two current 4-79 source pages. Corrosive, explosive, abrasive, sticky or hotter gases require different technical review.
03 · ORIGINAL CATALOGUE

4-79 Series Technical Specifications and Size Groups

The current original 4-79 catalogue page documents No.3A–No.20E, airflow 990–226,500 m³/h, total pressure 177–3,334 Pa, fan speed 260–2900 r/min and motor power 0.75–132 kW. These overall catalogue ranges are not one simultaneous operating point.

A Group — No.3 / 3.5 / 4 / 4.5 / 5 / 6

Compact motor-mounted catalogue group; check its original model performance and installation drawings.

C Group — No.7 / 8

Intermediate separate-shaft group with pulley, belt and motor drive; confirm the transmission specification.

E Group — No.10 / 12 / 14 / 16 / 18 / 20

Large group with original performance tables, V-belts, pulleys, motor guide rails and installation dimensions.

Catalogue Reference Conditions

Original catalogue reference: 20°C air, density 1.2 kg/m³ and atmospheric pressure 101325 Pa.

ParameterOriginal 4-79 Catalogue
ModelsNo.3A–No.20E
Airflow990–226,500 m³/h
Total pressure177–3,334 Pa
Fan speed260–2900 r/min
Motor power0.75–132 kW
Standard temperature≤80°C
Dust / hard particles≤150 mg/m³
Reference density1.2 kg/m³
Reference conditions20°C, 101325 Pa
The figures reproduce the current old-site 4-79 catalogue summary. Confirm the final fan size, speed and motor using one matching duty row from the original performance table, not the overall series envelope.
4-79 No.10 to No.20E outline and installation dimensions
4-79 No.10–20E installation and outline drawing.
04 · PURCHASE INFORMATION

Required Project Information

Operating Point

Airflow in m³/h and pressure in Pa at the same operating condition; duct resistance if pressure is unknown.

Gas and Temperature

Confirm temperature, dust, hard-particle loading, composition and any possible sticky material.

Motor and Transmission

Voltage, frequency, available space, preferred arrangement and control method.

Site Connection

Rotation, outlet angle, duct interface, base, foundation and access for maintenance.

05 · TYPICAL APPLICATIONS

Where the 4-79 Series Is Used

The original QIYUE 4-79 page documents ordinary industrial supply, exhaust and air-exchange duties. These examples remain subject to the specified gas, temperature, dust and system-resistance limits.

Factory & Workshop Ventilation

Air supply and exhaust for production buildings and industrial workshops with a confirmed pressure-loss calculation.

Large Building Air Exchange

General ventilation of large industrial buildings where the selected fan can deliver the design airflow against actual resistance.

Warehouse Air Circulation

Circulation and exhaust in warehouses handling ordinary non-corrosive air without viscous material.

Equipment Room Exhaust

General air exchange and heat removal for machinery and utility areas within catalogue temperature limits.

Drying and Process-Air Circulation

Review for suitable process-air duties only after confirming the actual inlet-gas temperature and medium.

Existing Fan Replacement

Compare the old unit’s nameplate, motor, rotation, discharge position, dimensions and measured duty point.

For system-level guidance see the industrial applications overview and the fan selection process. A category name does not replace performance-curve selection.

06 · FAQ

Buyer Questions About the 4-79 Series

Can this fan handle dusty or corrosive gas?

Standard operation is for non-corrosive gas without sticky substances. Source-page limits identify dust and hard particles not exceeding 150 mg/m³. Other conditions need separate engineering review.

What is the maximum airflow of the 4-79 series?

The current original catalogue page lists 990–226,500 m³/h for the No.3A–No.20E family. The actual selected model must meet airflow and pressure at the same operating point.

What should I supply for a quotation?

Send required airflow, pressure, medium condition, temperature, electricity details, outlet position, quantity and any original equipment dimensions or nameplate photos.

Which installation and drive arrangements are documented for 4-79?

The expanded old-site catalogue groups the series into A, C and E arrangements. Match the selected size and the corresponding original performance and dimensional tables before confirming a configuration.

What reference conditions are stated in the expanded catalogue?

The existing expanded 4-79 page lists 20°C air temperature, 1.2 kg/m³ reference density and 101325 Pa atmospheric pressure. These reference conditions are not the customer’s operating conditions; select using the actual project data.

Is 4-79 a direct replacement for 4-72?

No. Both are general industrial ventilation families, but the model size, performance curve, drive group and installation envelope must be checked separately.

What should be provided for a replacement-fan project?

Provide the old fan nameplate, photographs, existing motor data, airflow, pressure, rotation, outlet position, connection and foundation dimensions.

Review Your 4-79 Duty Point

Send the working conditions and drawings for an accurate project-specific fan proposal.