Original QIYUE FAN FBC extractive axial mine local ventilation fan
QIYUE FAN · EXTRACTIVE MINE VENTILATION

FBC Extractive Mine Local Ventilation Fan

A single-stage axial fan for negative-pressure local exhaust in underground mine workings. FBC draws contaminated air through ventilation ducting from headings and working areas to a designated return-air or exhaust route.

Select by airflow, total pressure, duct resistance, mine conditions and project safety requirements. FBC and FBCD are different configurations.

Original QIYUE FAN FBC extractive axial mine local ventilation fan
Airflow2,700–28,188 m³/h
Total pressure121–3,581 Pa
Motor power1.1–30 kW
ConfigurationSingle-stage · direct drive
01 · Engineering overview

Negative-Pressure Local Exhaust Ventilation

FBC is used when contaminated mine air must be extracted from a localized underground area rather than fresh air being forced toward the face. It is normally connected to negative-pressure ventilation ducting so air, dust and gas-bearing mine atmosphere can be drawn away from the working area and discharged into the designated return-air system.

Localized exhaust

Collect contaminated air near an excavation, heading or localized working zone.

Duct-connected duty

Match airflow and pressure to resistance through the complete suction duct route.

Browse Mine & Tunnel fan series →

02 · Ventilation principle

Extract Air Instead of Forcing Air

Working area

Contaminated air is collected near the excavation or localized working zone.

Negative-pressure duct

The fan creates suction through the duct rather than supplying positive-pressure fresh air.

FBC fan

A single-stage axial fan provides airflow and pressure to overcome duct-system resistance.

Discharge

Extracted air is discharged to the designated return-air or exhaust route.

Single-Stage Axial Exhaust Configuration

The official page describes an axial impeller, direct drive and cylindrical steel casing. Floor or suspended mounting can be reviewed according to the site layout. Confirm final configuration against the selected model and project drawings.

03 · Published reference range

FBC Series Performance Envelope

Use these values for preliminary screening. The official source page does not provide a complete standard model-by-model performance table; final selection must be checked against the required operating point and project configuration.

Published series envelope and configuration
ItemPublished value
Airflow0.75–7.83 m³/s / 2,700–28,188 m³/h
Total pressure121–3,581 Pa
Motor power1.1–30 kW
Typical speed1450 / 2900 rpm
DriveDirect drive

Reference procurement duty examples

These examples are reference project duties. Confirm model-specific performance at the required operating point before quotation.

Reference modelPowerProject dutyVoltage
FBC No.6.022 kW≥250 m³/min at 2,000 Pa660 / 1140 V
FBC No.7.545 kW≥400 m³/min at 3,000 Pa660 / 1140 V
Data boundary: The 45 kW project example is retained as published even though the general FBC envelope lists 1.1–30 kW. It is not a claim that 45 kW is within the general range. Confirm the supplied fan and motor against the approved duty point.
04 · Product difference

FBC and FBCD Are Not Interchangeable by Name

FBC · Single-stage extractive fan

Used where one axial stage can meet required airflow and pressure for negative-pressure local exhaust.

FBCD · Contra-rotating extractive fan

Uses two contra-rotating stages and is generally used where greater pressure capability is required.

View FBCD extractive local fan →

Mine safety, explosion-protection level, motor specification and certification documents must be confirmed for the destination market and project. The source page does not specify a universal approval for every FBC configuration.
05 · Selection and replacement

Send the Mine Ventilation Duty and Duct Data

Operating point

Required airflow, pressure basis and system pressure loss.

Duct route

Duct diameter, total length, leakage, bends and discharge route.

Mine conditions

Mine type, gas and dust conditions, temperature, altitude and safety requirements.

Electrical and installation

Voltage, frequency, motor, mounting, quantity and destination.

Industrial Fan Selection Guide → · Contact / RFQ →

06 · FAQ

FBC Mine Ventilation Fan Questions

What does FBC mean?

FBC identifies an extractive axial local ventilation fan. Contra-rotating models add D and are identified as FBCD.

What is the difference between FBC and FBCD?

FBC uses a single-stage configuration. FBCD uses two contra-rotating stages and is generally used where greater pressure capability is required.

What airflow range does the source publish?

0.75–7.83 m³/s or 2,700–28,188 m³/h, with total pressure of 121–3,581 Pa.

Submit the Operating Point Before Model Confirmation

Send airflow, pressure, duct dimensions and mine conditions for project review.

SEND FBC RFQ WHATSAPP