QIYUE FAN / MINERAL PROCESSING
Conveyor Transfer-Point Dust Extraction: Define the Enclosure Before the Fan
At a mineral transfer point, the material brings air into the receiving enclosure as it falls. A replacement fan enquiry therefore needs the transfer geometry and operating condition, not only conveyor throughput or the old motor rating.

Separate material movement from extraction airflow
Illustrative review sequence, not a conveyor or ventilation design.
NIOSH identifies transfer enclosures, curtains and skirting as important controls. Reducing unnecessary openings and avoiding abrupt material-flow changes help contain the release. The extraction takeoff also needs a suitable location so it captures airborne dust without unnecessarily drawing large pieces into the duct.
Check why dust is escaping
An undersized receiving enclosure can become pressurized by the air carried in with falling material. NIOSH also distinguishes dust from loading, travel on the belt, discharge and return-side carryback. These sources do not necessarily respond to the same extraction change.
Before requesting more fan power, record where the release occurs and whether it coincides with a changed drop, missing curtain, worn skirt or a new loading pattern. If the problem is dried carryback falling from return idlers, inspect the belt-cleaning arrangement instead of assuming that a larger transfer-point fan will solve it.
Include crushers and upstream changes in the review
NIOSH describes feed and discharge points as primary dust-release locations around crushing and grinding equipment. Incoming material entrains air, while worn seals and enlarged openings change the amount of air the extraction system must handle. Wet suppression and local exhaust may be used separately or together according to the process.
A new crusher, revised chute or changed moisture regime should therefore be shown on the enquiry drawing. State which transfers operate together. The ventilation designer should establish capture requirements and branch airflow; the fan quotation should address the resulting system duty, not infer airflow from tonnes per hour.
Specify the medium at the fan, not just the conveyed mineral
Mark whether the fan sits upstream or downstream of the collector. Provide expected residual dust, particle characteristics, moisture and temperature at its inlet. Abrasive particles, buildup and a changed filter resistance affect different parts of the selection review.
Use the baghouse fan selection guide for collector resistance and placement, and the C6-48 product page for its documented operating range. A dust-duty model name alone does not establish suitability for every mineral, concentration or abrasive load.
Agree the site verification scope
Compare the required duty with the proposed curve, motor, construction and installation interfaces. Keep the process state and measurement locations consistent when comparing before-and-after readings. Fan airflow alone does not demonstrate control of respirable silica exposure; the site’s competent team should define the exposure assessment and acceptance requirements.
For downstream packing operations, use the mineral powder bagging extraction guide to record filling, bag-release and transfer interfaces separately.
Discuss a transfer-point extraction fan →
Technical references: NIOSH Engineering Controls Database, Transfer Points, Conveying and Crushing & Grinding.