GY6-41 Industrial Boiler Blower and Induced Draft Fan

GY6-41 serves small and medium industrial boiler rooms. G6-41 supplies clean combustion air; Y6-41 extracts flue gas after combustion and dust removal. Select each side against its own medium, system resistance and site layout.

GY6-41 Industrial Boiler Blower and Induced Draft Fan
G6-41 dutyBoiler blowerClean combustion air
Y6-41 dutyInduced draftFlue gas extraction
Boiler reference0.5–10 t/hIndustrial boiler rooms
Project checkLayout + dutyRotation, outlet, pressure

GY6-41 Industrial Boiler
Blower and Induced Draft Fan

GY6-41 is designed for 0.5–10 t/h industrial boilers using different coal types and equipped with smoke and dust-removal systems. It supports both combustion-air supply and flue-gas exhaust in small and medium boiler rooms.

G6-41 works as the boiler blower on the clean-air side. Y6-41 works as the induced-draft fan after combustion and dust removal.

Final selection should include boiler capacity, fan position, airflow, pressure, medium temperature, dust concentration, drive type, outlet angle and site installation layout.

Focused on small and medium boiler rooms using 0.5–10 t/h industrial boilers.

G6-41 delivers clean air to support stable boiler combustion.

Y6-41 removes flue gas after combustion and dust treatment.

Left/right rotation and multiple outlet angles match different duct layouts.

Built for Small and Medium Industrial Boiler Rooms

Unlike large thermal-power boiler fan series, GY6-41 is positioned for industrial boiler rooms where stable air supply, reliable smoke exhaust, compact installation and manageable motor power are more important than extreme capacity.

The G6-41 blower supplies combustion air before the boiler. The Y6-41 induced draft fan handles flue gas after combustion and dust removal. The two directions can be matched as a boiler-room air and gas system.

How G6-41 and Y6-41 Work Together

G6-41 blower delivers air into the boiler combustion system.

Airflow and pressure are matched with boiler capacity and duct resistance.

Dust-control equipment adds resistance before the exhaust fan.

Y6-41 removes flue gas and supports negative pressure.

Blower and Induced-Draft Comparison

Selection Point G6-41 Boiler Blower Y6-41 Induced Draft Fan What to Confirm
Fan Position Before combustion After combustion and dust removal Complete boiler air-path layout
Medium Clean air Boiler flue gas Temperature, dust and corrosion
Temperature Normally ≤80°C Normally ≤250°C Continuous and peak temperature
Drive Type A type or D type C type or D type Speed, motor, maintenance and space

GY6-41 Configuration Reference

Item Configuration Description
Fan Series GY6-41 industrial boiler fan series
Boiler Range 0.5–10 t/h industrial boiler
G6-41 Drive A type or D type drive for boiler blower applications
Y6-41 Drive C type or D type drive for induced-draft applications
Rotation Direction Right-hand or left-hand rotation according to site layout
Outlet Angle 0°, 90°, 180°, 270°, or customized angle when required
Selection Basis Boiler capacity, airflow, pressure, temperature, dust concentration and installation layout

G6-41 Boiler Blower Models

Representative data for preliminary clean-air-side model comparison.

Model Speed Air Volume Total Pressure Power Type
3.3A 2825 r/min 1,090–2,301 m³/h 954–1,936 Pa 1.1 kW G
5.4A 1420 r/min 2,357–5,514 m³/h 833–1,264 Pa 3 kW G
6.4A 1440 r/min 4,210–10,348 m³/h 1,029–1,852 Pa 5.5 kW G
7.1A 1440 r/min 4,418–11,350 m³/h 1,234–2,244 Pa 7.5 kW G
8.5A 1470 r/min 6,482–17,330 m³/h 2,518–3,253 Pa 18.5 kW G

Y6-41 Induced Draft Models

Representative data for preliminary flue-gas-side model comparison.

Model Speed Air Volume Total Pressure Power Type
4.5C 2025 r/min 2,317–4,970 m³/h 1,667–2,327 Pa 4 kW Y
5.4C 2600 r/min 4,234–10,002 m³/h 1,440–2,528 Pa 7.5 kW Y
7.1C 2100 r/min 11,408–16,300 m³/h 1,975–2,794 Pa 15 kW Y
9C 1640 r/min 13,964–28,130 m³/h 1,662–2,955 Pa 22 kW Y
10C 1600 r/min 16,620–35,157 m³/h 2,710–3,611 Pa 37 kW Y
11.2C 1480 r/min 24,961–47,591 m³/h 2,043–3,618 Pa 45 kW Y

Where GY6-41 Is Commonly Used

Compact boiler-room air supply and exhaust for daily industrial operation.

Matched blower and ID fan directions for common coal-fired boiler systems.

Suitable for processing plants, workshops and industrial heating systems.

Works with treatment equipment where resistance is included in selection.

G6-41 supplies combustion air according to boiler demand.

Information Required for Fan Selection

Confirm boiler capacity and whether the requirement is blower or induced draft.

Provide required airflow and static or total pressure basis.

Confirm air or flue gas temperature, dust concentration and corrosion risk.

Provide drive type, outlet angle, rotation, voltage and available space.

Use the product-family and system pages to confirm the clean-air or flue-gas side. Specific product links remain available for direct comparison.

Get a GY6-41 Boiler Room Fan Quote

Send boiler capacity, fan role, airflow, pressure, temperature, dust concentration, drive type, outlet angle, rotation, voltage and installation space.

Send Your Operating Conditions

Airflow, pressure, gas medium, temperature, voltage and quantity.

REQUEST A QUOTE ↗