GY6-41 Industrial Boiler Blower and Induced Draft Fan
GY6-41 serves small and medium industrial boiler rooms. G6-41 supplies clean combustion air; Y6-41 extracts flue gas after combustion and dust removal. Select each side against its own medium, system resistance and site layout.

GY6-41 Industrial Boiler
Blower and Induced Draft Fan
GY6-41 is designed for 0.5–10 t/h industrial boilers using different coal types and equipped with smoke and dust-removal systems. It supports both combustion-air supply and flue-gas exhaust in small and medium boiler rooms.
G6-41 works as the boiler blower on the clean-air side. Y6-41 works as the induced-draft fan after combustion and dust removal.
Final selection should include boiler capacity, fan position, airflow, pressure, medium temperature, dust concentration, drive type, outlet angle and site installation layout.
Focused on small and medium boiler rooms using 0.5–10 t/h industrial boilers.
G6-41 delivers clean air to support stable boiler combustion.
Y6-41 removes flue gas after combustion and dust treatment.
Left/right rotation and multiple outlet angles match different duct layouts.
Built for Small and Medium Industrial Boiler Rooms
Unlike large thermal-power boiler fan series, GY6-41 is positioned for industrial boiler rooms where stable air supply, reliable smoke exhaust, compact installation and manageable motor power are more important than extreme capacity.
The G6-41 blower supplies combustion air before the boiler. The Y6-41 induced draft fan handles flue gas after combustion and dust removal. The two directions can be matched as a boiler-room air and gas system.
How G6-41 and Y6-41 Work Together
G6-41 blower delivers air into the boiler combustion system.
Airflow and pressure are matched with boiler capacity and duct resistance.
Dust-control equipment adds resistance before the exhaust fan.
Y6-41 removes flue gas and supports negative pressure.
Blower and Induced-Draft Comparison
| Selection Point | G6-41 Boiler Blower | Y6-41 Induced Draft Fan | What to Confirm |
|---|---|---|---|
| Fan Position | Before combustion | After combustion and dust removal | Complete boiler air-path layout |
| Medium | Clean air | Boiler flue gas | Temperature, dust and corrosion |
| Temperature | Normally ≤80°C | Normally ≤250°C | Continuous and peak temperature |
| Drive Type | A type or D type | C type or D type | Speed, motor, maintenance and space |
GY6-41 Configuration Reference
| Item | Configuration Description |
|---|---|
| Fan Series | GY6-41 industrial boiler fan series |
| Boiler Range | 0.5–10 t/h industrial boiler |
| G6-41 Drive | A type or D type drive for boiler blower applications |
| Y6-41 Drive | C type or D type drive for induced-draft applications |
| Rotation Direction | Right-hand or left-hand rotation according to site layout |
| Outlet Angle | 0°, 90°, 180°, 270°, or customized angle when required |
| Selection Basis | Boiler capacity, airflow, pressure, temperature, dust concentration and installation layout |
G6-41 Boiler Blower Models
Representative data for preliminary clean-air-side model comparison.
| Model | Speed | Air Volume | Total Pressure | Power | Type |
|---|---|---|---|---|---|
| 3.3A | 2825 r/min | 1,090–2,301 m³/h | 954–1,936 Pa | 1.1 kW | G |
| 5.4A | 1420 r/min | 2,357–5,514 m³/h | 833–1,264 Pa | 3 kW | G |
| 6.4A | 1440 r/min | 4,210–10,348 m³/h | 1,029–1,852 Pa | 5.5 kW | G |
| 7.1A | 1440 r/min | 4,418–11,350 m³/h | 1,234–2,244 Pa | 7.5 kW | G |
| 8.5A | 1470 r/min | 6,482–17,330 m³/h | 2,518–3,253 Pa | 18.5 kW | G |
Y6-41 Induced Draft Models
Representative data for preliminary flue-gas-side model comparison.
| Model | Speed | Air Volume | Total Pressure | Power | Type |
|---|---|---|---|---|---|
| 4.5C | 2025 r/min | 2,317–4,970 m³/h | 1,667–2,327 Pa | 4 kW | Y |
| 5.4C | 2600 r/min | 4,234–10,002 m³/h | 1,440–2,528 Pa | 7.5 kW | Y |
| 7.1C | 2100 r/min | 11,408–16,300 m³/h | 1,975–2,794 Pa | 15 kW | Y |
| 9C | 1640 r/min | 13,964–28,130 m³/h | 1,662–2,955 Pa | 22 kW | Y |
| 10C | 1600 r/min | 16,620–35,157 m³/h | 2,710–3,611 Pa | 37 kW | Y |
| 11.2C | 1480 r/min | 24,961–47,591 m³/h | 2,043–3,618 Pa | 45 kW | Y |
Where GY6-41 Is Commonly Used
Compact boiler-room air supply and exhaust for daily industrial operation.
Matched blower and ID fan directions for common coal-fired boiler systems.
Suitable for processing plants, workshops and industrial heating systems.
Works with treatment equipment where resistance is included in selection.
G6-41 supplies combustion air according to boiler demand.
Information Required for Fan Selection
Confirm boiler capacity and whether the requirement is blower or induced draft.
Provide required airflow and static or total pressure basis.
Confirm air or flue gas temperature, dust concentration and corrosion risk.
Provide drive type, outlet angle, rotation, voltage and available space.
Continue from GY6-41 to Product Family, System and Related Models
Use the product-family and system pages to confirm the clean-air or flue-gas side. Specific product links remain available for direct comparison.
Get a GY6-41 Boiler Room Fan Quote
Send boiler capacity, fan role, airflow, pressure, temperature, dust concentration, drive type, outlet angle, rotation, voltage and installation space.
Send Your Operating Conditions
Airflow, pressure, gas medium, temperature, voltage and quantity.