6-27 Series / Small Airflow · High Pressure
6-27 High-Pressure Centrifugal Fan
6-27 is a compact high-pressure centrifugal fan developed for industrial duties requiring relatively small airflow with significantly higher pressure. It is suitable for process air supply, equipment ventilation, laboratory systems, glass processing and other high-resistance air-handling applications.
72–621 m³/h 6,600–7,492 Pa 2.2 kW

AIRFLOW
72–621 m³/h
TOTAL PRESSURE
6,600–7,492 Pa
SPEED
2900 rpm
DRIVE
A-Type Direct
6-27 Series
Technical Index
01 Overview 02 Duty Position 03 Construction 04 Performance 05 Medium 06 Orientation 07 Selection 08 Related Fans 09 Resources 10 FAQ
Quick Facts
Small Airflow
High Pressure
2900 rpm
A-Type Direct Drive
Industrial Process Air
High Pressure
2900 rpm
A-Type Direct Drive
Industrial Process Air
01 / Engineering Overview
Pressure-First Fan for Small Airflow Duties
The 6-27 series occupies a different operating region from ordinary factory ventilation fans. Its airflow is relatively small, while available pressure is significantly higher.
This makes the fan suitable for equipment requiring concentrated high-pressure air delivery rather than large-volume room ventilation.
02 / Duty Position
When 6-27 Makes Sense
Small Airflow
Applications where only a limited volume of process air is required.
High Resistance
Systems with restrictive equipment, small passages or process components requiring high available pressure.
Process Air
Forced air for instruments, laboratory equipment, glass processing and selected industrial processes.
Not General Ventilation
For high-volume workshop ventilation, a general-purpose centrifugal or axial fan is usually more appropriate.
03 / Construction
Compact Direct-Driven Centrifugal Arrangement
01
Single Inlet
Compact centrifugal air path for concentrated pressure generation.
02
A-Type Drive
Impeller is directly driven by the motor for a compact overall arrangement.
03
High-Speed Duty
Reference performance is based on approximately 2900 rpm operation.
04
Filter Option
Legacy 6-27 configurations may include an inlet filter for clean forced-air applications.
04 / Reference Performance
6-27 Reference Duty Points
Reference speed: 2900 rpm. Published legacy catalog data is shown for preliminary engineering screening.
| POINT | AIRFLOW m³/h | TOTAL PRESSURE Pa | EFFICIENCY % | MOTOR |
|---|---|---|---|---|
| 1 | 72 | 7,492 | 62 | 2.2 kW |
| 2 | 120 | 7,463 | 74 | 2.2 kW |
| 3 | 140 | 7,453 | 77.5 | 2.2 kW |
| 4 | 182 | 7,357 | 82 | 2.2 kW |
| 5 | 240 | 7,277 | 82 | 2.2 kW |
| 6 | 301 | 7,061 | 76 | 2.2 kW |
| 7 | 574 | 6,800 | 50 | 2.2 kW |
| 8 | 621 | 6,600 | 45 | 2.2 kW |
These values are reference catalog performance points. Final supplied performance should be confirmed against the selected QIYUE configuration, inlet arrangement and actual operating conditions.
05 / Medium Conditions
Designed Primarily for Clean Industrial Air
Medium
Air or other non-hazardous gases compatible with the fan material.
Temperature
Reference catalog condition: maximum approximately 55°C.
Particle Loading
Reference limit for dust and hard particles: ≤150 mg/m³.
Special Gas
Corrosive, explosive, hot or heavily dust-laden media require separate engineering review.
06 / Rotation & Outlet
Confirm Rotation and Discharge Before Production
Rotation
Clockwise or counter-clockwise according to the required installation arrangement.
0°
Reference discharge orientation available in legacy configurations.
90°
Alternative outlet arrangement for duct routing.
180°
Alternative discharge orientation depending on installation.
07 / Selection Information
What to Send for 6-27 Selection
01 · Airflow – Required operating airflow in m³/h.
02 · Pressure – Required static or total pressure in Pa or kPa.
03 · Medium – Clean air, gas composition, dust content and humidity.
04 · Temperature – Normal and maximum operating temperature.
05 · Filter – Confirm whether an inlet filtration arrangement is required.
06 · Rotation – Clockwise / counter-clockwise and outlet orientation.
07 · Electrical – Voltage, frequency, phase and quantity.
09 / Technical Resources
Selection References
10 / FAQ
6-27 High-Pressure Fan Questions
What is the main characteristic of the 6-27 fan?
The 6-27 series is characterized by very small airflow combined with relatively high pressure, making it different from ordinary industrial ventilation fans.
What is the reference airflow range?
Published reference performance covers approximately 72 to 621 m³/h.
What pressure can the fan provide?
Reference performance points cover approximately 6,600 to 7,492 Pa total pressure.
Is 6-27 suitable for workshop ventilation?
Normally no. Its operating region is better suited to small-volume high-pressure process air than large-space general ventilation.
Can the fan handle high-temperature gas?
The standard reference configuration is intended for relatively low-temperature gas. Higher-temperature duties require a different fan configuration and engineering review.
What information is needed before quotation?
Provide airflow, pressure, medium, temperature, inlet condition, rotation, outlet direction, voltage, frequency and quantity.
6-27 High-Pressure Fan Selection
Send the Required Small-Flow High-Pressure Duty.
Airflow · Pressure · Medium · Temperature · Inlet Filter · Rotation · Outlet Angle · Voltage · Frequency · Quantity