Original QIYUE FAN FK and FKD metal mine local ventilation fan
QIYUE FAN · METAL & NON-COAL MINES

FK / FKD Metal Mine Local Ventilation Fans

Local forced ventilation for metal mines and other non-coal underground workings. FK covers single-stage duties; FKD uses a contra-rotating, two-motor configuration for higher-resistance and longer duct systems.

Select against required face airflow, duct diameter and length, system resistance, mine conditions and electrical supply.

Original QIYUE FAN FK / FKD metal mine local ventilation fan
Airflow range3,240–64,080 m³/h
Pressure range475–3,776 Pa
Duct diameter300–800 mm
ConfigurationsFK / FKD
01 · Engineering overview

Local Air Supply for Underground Metal Mine Workings

FK and FKD fans are used for localized forced ventilation in metal mines and other non-coal underground workings, including development, drifting and single-heading excavation where fresh air must be delivered through ventilation ducting to the working face.

The source recommends considering duct diameter, total duct length, leakage, bends and required face airflow. FKD contra-rotating models serve operating points requiring more pressure and longer air-delivery distances.

Product boundary: FK / FKD are not the same product family as FB / FBD. This page covers metal and non-coal mine local ventilation. Coal-mine and explosion-protection requirements need separate project review.

Browse Mine & Tunnel fans → · FBC extractive fan →

02 · Configuration

Choose FK or FKD by System Resistance

FK · Single-stage / auxiliary

Suitable where one stage can satisfy airflow, duct resistance and delivery distance.

FKD · Contra-rotating

Two impeller stages rotate in opposite directions for a higher-pressure operating range on longer or higher-resistance ducts.

FKD50 is listed with two motors. Confirm the project model, motor arrangement and duty point before substitution or replacement.

03 · Published reference performance

FK Single-Stage Series

Airflow is shown in m³/s and m³/h as on the source page. Pressure ranges below retain the source’s value order. Use these as preliminary references; actual airflow at the working face depends on duct resistance, leakage, altitude and air density.

FK series reference performance
ModelPower (kW)Airflow (m³/s)Airflow (m³/h)Pressure (Pa)Duct (mm)
FK58-1 No.31.50.9–1.43,240–5,040928–575300
FK58-1 No.3.531.5–2.45,400–8,6401263–752350
FK58-1 No.45.52.2–3.57,920–12,6001648–1020400
FK58-1 No.4.5113.1–5.011,160–18,0002093–1295450
FK58-2 No.4112.2–3.57,920–12,6002923–1811400
FK55-2 No.4.5113.0–5.210,800–18,7202276–1275450
FK55-1 No.5114.2–6.615,120–23,7601726–1324450
FK56-1 No.3.152.21.4–2.15,040–7,560853–588300
FK56-1 No.442.1–3.47,560–12,2401275–981400
FK67-1 No.4.57.52.6–4.29,360–15,1202256–1177400
FK67-2 No.4.5112.8–4.310,080–15,4803237–1471400
FK67-1 No.5.25284.0–6.314,400–22,6803776–2648500
FK40-1 No.5.55.54.3–5.115,480–18,360633–475550
FK40-1 No.6.5117.1–8.425,560–30,240884–663650
FK40-1 No.7158.8–10.531,680–37,8001025–769700
FK40-1 No.7.52210.9–12.939,240–46,4401177–883750
FK40-1 No.83013.2–15.647,520–56,1601339–1005800

FKD Contra-Rotating Series

FKD50 uses a contra-rotating two-motor configuration for higher-pressure local ventilation.

FKD50 reference performance
ModelPower (kW)Airflow (m³/s)Airflow (m³/h)Pressure (Pa)Duct (mm)
FKD50 No.5.52×5.54.8–5.817,280–20,8801182–515550
FKD50 No.6.52×117.9–9.528,440–34,2001651–719650
FKD50 No.72×159.9–11.935,640–42,8401915–834700
FKD50 No.7.52×2212.2–14.643,920–52,5602198–957750
FKD50 No.82×3014.8–17.853,280–64,0802501–1089800
Final model choice must consider actual duct resistance, leakage, altitude, air density and the airflow required at the working face.
04 · Installation reference

Representative Fan Dimensions

These are source catalog reference values. Confirm the selected model and final GA drawing before fabricating supports, duct adapters or foundations.

ModelDuct (mm)Distance (m)Outer Ø (mm)Length (mm)Center H (mm)
FK58-1 No.330080390486230
FK58-1 No.4400200520649290
FK58-2 No.4400400520877290
FK67-1 No.5.255006006201364310
FKD50 No.5.55501809483800337
FKD50 No.880022013404350485
05 · Application fit

Local Ventilation in Metal and Non-Coal Mines

Development headings

Deliver fresh air to underground development and drifting faces.

Single-heading excavation

Forced ventilation where natural through-flow is unavailable.

Long duct runs

FKD contra-rotating configurations for higher-resistance temporary systems.

Metal and non-coal mines

Local ventilation for underground metal ore and other non-coal mining projects.

06 · Selection and replacement

What to Send for FK / FKD Selection

Airflow at the face

Required volume at the working area.

Duct diameter and length

Flexible or rigid duct diameter and total fan-to-face distance.

System resistance

Known pressure loss, layout, bends and leakage condition.

Mine and electrical conditions

Mine type, gas/dust hazards, voltage, frequency, phase and starting method.

For replacement projects, include the old model, nameplate, motor data, duct diameter and available installation dimensions. FK and FKD may appear in older project records alongside JK and DJK designations; verify the actual duty and interfaces before replacement.

Fan Selection Guide → · Contact / RFQ →

07 · FAQ

FK / FKD Mine Ventilation Questions

What is the difference between FK and FKD?

FK covers single-stage local ventilation. FKD uses a contra-rotating two-stage arrangement with two motors in the listed FKD50 data.

Are FK / FKD coal-mine fans?

This source page positions FK / FKD for metal and other non-coal underground mine duties. Coal-mine and explosion-protection requirements need separate review.

Can an FK or FKD replace an older JK or DJK fan?

Replacement can be reviewed from the existing model and nameplate, duty point, motor data, duct diameter and installation dimensions. Do not substitute on model name alone.