Greenhouse Exhaust Fan Replacement: Compare Installed Duty, Not Diameter Alone

A replacement that fits the same wall opening may not deliver the same ventilation. Prepare the existing installation details and the greenhouse designer’s required operating duty, then compare the proposed fan with the accessories and controls it will actually use.

First establish why replacement is needed

UF/IFAS’s maintenance guide identifies dirty blades, restricted shutters, belt condition, incorrect rotation and inlet or discharge obstructions as causes of reduced performance. Have authorized maintenance personnel document the condition under the manufacturer’s procedures before treating weak ventilation as proof that a larger fan is required.

Restore the existing installation

If a service issue is identified, record the work completed and the subsequent operating evidence. Keep that record with the replacement enquiry so suppliers are not selecting against an unexplained maintenance fault.

Change the ventilation duty

If pads, openings, layout or the required operating strategy are changing, request the revised duty from the greenhouse designer. Label this as a changed-duty project, not simply a matching-diameter replacement.

Compare airflow at the same resistance

UF/IFAS’s fan-selection guide bases selection on airflow at the expected static pressure, with cooling-pad pressure loss obtained from the pad manufacturer. It also identifies installation space, noise, efficiency and economics as selection factors.

In your comparison sheet, request the selected point on each fan curve and the rating conditions. Identify whether the quoted performance includes the proposed shutter, guard and other accessories. A free-air figure should not be treated as the installed result for a system with resistance.

Make a fit-and-scope record

Photograph the complete assembly from both sides where safely accessible. Label the wall opening and fan housing separately, and reference the existing mounting drawing if available. Ask the supplier to state exactly which parts are included.

Existing fan manufacturer / model / equipment tag:
Wall opening and mounting dimensions:
Fan housing and connection drawing:
Shutter / guard / cone or discharge accessory:
Retained items and items to replace:
Electrical supply and existing control arrangement:
Required airflow / static pressure / rating conditions:
Proposed fan curve and accessory configuration:
Installation access and service-clearance constraints:
Quantity / delivery location / required replacement window:

Keep controls and staged operation visible

List the current fan groups and the intended operating combinations. Identify the existing controller and who will verify compatibility with the proposed motor and control method. Do not assume that a new fan supports the old speed-control arrangement merely because voltage and rated power look similar.

Where shutters or inlet devices are separately supplied, assign responsibility for their coordination with the fans. Request the relevant wiring and control documentation from the responsible suppliers; do not make changes based on a generic online diagram.

Evaluate running cost on a common basis

For each offer, request input-power information at the same required duty and state the assumed hours in each operating mode. Keep equipment cost, accessories, installation work and projected energy cost separate. Use the annual fan energy-cost comparison to organize the calculation, not the motor nameplate alone.

Agree the handover before ordering

Ask who will check mounting, rotation, controls and the agreed installed performance, and which records will be delivered. A fan selection does not promise a particular crop temperature or yield; the greenhouse climate outcome depends on the complete design and operating conditions.

Continue with the wall-mounted fan interface checklist, fan curve guide and quotation scope comparison. For a possible supply review, start with the defined duty rather than an assumed catalog equivalent.