T35-11 / BT35-11 axial flow fan is a direct-drive industrial ventilation fan designed for large airflow and low-resistance air exchange. It is suitable for workshop ventilation, warehouse exhaust, equipment-room cooling, wall-mounted exhaust and short-duct ventilation systems.

T35-11 is used for general industrial ventilation. BT35-11 can be configured with an explosion-proof motor and related electrical components for projects requiring explosion-proof ventilation. Final model selection should be confirmed according to airflow, pressure, voltage, installation method, medium condition and explosion-proof requirement.

Straight-through axial airflow · direct-drive structure · wall, duct or support-frame installation.

T35-11 / BT35-11 axial flow fan
1,500–67,900 m³/hReference airflow
39–474 PaReference total pressure
No. 2.8–11.2Reference fan size
0.18–7.5 kWCommon motor range

Configuration difference

T35-11 General Type vs BT35-11 Configuration

The T35-11 / BT35-11 axial fan moves air in the same direction as the fan axis. Its direct-drive structure is suited to compact installations with relatively low system resistance.

Swipe horizontally to view the full table.

ItemT35-11 Axial Flow FanBT35-11 Configuration
Primary useGeneral industrial ventilationVentilation requiring explosion-proof electrical configuration
MotorStandard industrial motorExplosion-proof motor selected by project requirement
Working areaNon-hazardous industrial areaHazardous-area ventilation only after formal requirement confirmation
Additional data requiredAirflow, pressure, voltage and installationExplosion-proof grade, gas group, temperature class, certificate and wiring method

For BT35-11, the project review must cover the complete fan construction, electrical equipment and applicable documentation against the specified hazardous area. An explosion-protected motor alone does not establish suitability of the complete assembly.

Operating boundary

Suitable Conditions and Cases Requiring Another Fan Type

Suitable conditions

  • Large airflow with low system resistance
  • Workshop and warehouse air exchange
  • Wall-mounted exhaust ventilation
  • Equipment-room cooling and exhaust
  • Short-duct ventilation

Not the first choice

  • Long ducts with high resistance
  • Bag filters and dust collectors
  • Boiler draft and hot flue gas
  • Heavy or abrasive dust
  • Strongly corrosive gas without special design

For long ducts, filters, baghouses or systems requiring high static pressure, compare a centrifugal fan against the calculated operating point.

Technical summary

Reference Technical Parameters

Swipe horizontally to view the full table.

Product seriesT35-11 / BT35-11
Fan typeDirect-drive axial flow fan
Fan sizeNo. 2.8–11.2
Impeller diameterApprox. 280–1120 mm
Reference airflowApprox. 1,500–67,900 m³/h
Reference total pressureApprox. 39–474 Pa
Reference speed960 / 1450 / 2900 r/min
Motor power0.18–7.5 kW common range; other configurations by confirmation
Reference blade angle15° / 20° / 25° / 30° / 35°
Reference blade quantity4 blades
Voltage220 V / 380 V; other voltage and frequency by confirmation
InstallationWall-mounted, duct-mounted, floor support or customized support frame
MediumClean air or specified non-corrosive gas

These are preliminary reference ranges, not a continuous performance curve. Final airflow, pressure, power and dimensions depend on fan size, blade angle, speed, motor configuration and operating condition.

Model reference

Typical T35 / BT35 Model Data

The following data is preserved for preliminary comparison. Check the selected operating point and the manufacturer’s model data before final selection.

Swipe horizontally to view the full table.

ModelSpeedAirflow referencePressure referenceMotor power reference
No. 2.81450 / 2900 r/min1,500–3,200 m³/h60–232 Pa0.18–0.25 kW
No. 3.151450 / 2900 r/min2,270–4,545 m³/h74–373 Pa0.25–0.37 kW
No. 3.551450 / 2900 r/min3,265–6,542 m³/h93–373 Pa0.37–0.75 kW
No. 41450 / 2900 r/min4,687–9,336 m³/h119–474 Pa0.55–1.1 kW
No. 4.51450 r/min6,658 m³/h150 Pa0.55 kW
No. 51450 r/min9,133 m³/h185 Pa0.75 kW
No. 5.61450 r/min12,812 m³/h232 Pa1.1 kW
No. 6.31450 r/min18,250 m³/h294 Pa1.5 kW
No. 7.1960 / 1450 r/min17,296–26,120 m³/h164–373 Pa1.5–3 kW
No. 8960 / 1450 r/min24,739–37,370 m³/h208–474 Pa2.2–4 kW
No. 9960 r/min35,227 m³/h263 Pa3 kW
No. 10960 r/min48,326 m³/h321 Pa4 kW
No. 11.2960 r/min67,892 m³/h407 Pa7.5 kW

Structure and installation

Direct-Drive Axial Fan Construction

The fan mainly consists of a cylindrical casing, axial impeller, hub, direct-drive motor, protective guard, flange and support structure.

Cylindrical casing

Guides airflow and provides the duct or wall connection.

Axial impeller

Produces straight-through airflow along the fan axis.

Direct-drive motor

Reduces transmission components and keeps the structure compact.

Guard and flange

Configured according to installation and safety requirements.

Wall, Duct and Support-Frame Installation

T35-11 and BT35-11 can be supplied for wall-mounted installation, short-duct connection, floor support or project-specific mounting structures.

For wall exhaust installations, coordinate the louver, guard, shutter and replacement-air path before confirming the fan duty and mounting arrangement.

  • Wall-opening ventilation for workshops and warehouses
  • Short-duct air supply or exhaust
  • Equipment-room heat exhaust
  • Platform or foundation support
  • Customized flange, guard, support frame or rain cover
T35-11 / BT35-11 axial flow fan installation drawing
T35-11 / BT35-11 installation drawing. Open full-size drawing; match the selected size and configuration before confirming the opening or flange.

BT35 safety configuration

Explosion-Proof Requirements Must Be Confirmed Before Production

Specify the hazardous-area requirement for the complete BT35-11 assembly, including mechanical construction and electrical equipment. Have the responsible engineer review the proposed configuration and scope of its supporting certificates before ordering.

Swipe horizontally to view the full table.

Explosion-proof gradeConfirm before quotation
Gas groupConfirm from site classification
Temperature classConfirm from project requirement
CertificateSpecify required standard or certification
Wiring methodConfirm junction box and cable-entry requirement
BT35-11 explosion-proof motor junction box detail
BT35-11 explosion-proof motor junction box detail.

Purchase package

Confirm the Opening, Air Direction and Accessory Scope

Wall-Opening Replacement

Send the opening width, height and wall thickness, mounting-frame details, and photographs from both sides. Mark the required airflow direction on a sketch. Identify whether the existing louvre or shutter stays in place.

Short-Duct Replacement

Send the mating flange dimensions, bolt pattern, available casing length, support position and nearby bends. Pair the installation sketch with the required airflow and installed resistance; nominal fan diameter alone does not establish fit or duty.

Fan Only or Complete Package?

List the fan, motor, guard, flange, support frame, shutter, weather protection and controls separately as supplied, retained or installer-provided. Include retained accessories in the resistance review.

One Selection, One Drawing

Request fan size, blade angle, speed, motor and operating point on the same selection record. Ask for a matching outline drawing with airflow direction, electrical connection location and service access.

For greenhouse replacement projects, review the greenhouse air path and existing accessories alongside the fan request.

Send installation photographs and fan requirements →

Selection information

What to Provide for Correct Axial Fan Selection

Required airflow

Provide the required air volume in m³/h and any expected operating range.

System resistance

Provide pressure or duct-resistance data to confirm whether an axial fan is suitable.

Installation method

Wall opening, duct connection, floor support, flange size and available space.

Medium condition

Confirm air composition, temperature, dust, moisture and corrosion conditions.

Electrical supply

Provide voltage, frequency, phase, protection level and preferred motor standard.

Explosion-proof requirement

For BT35, provide grade, gas group, temperature class and certificate requirement.

Typical Ventilation Applications

  • General factory ventilation for workshops and industrial buildings
  • Large-airflow exchange in warehouses and enclosed spaces
  • Heat removal and cooling ventilation for equipment rooms
  • Air movement through short ducts with relatively low resistance
  • Direct air discharge through wall openings and louvers
  • BT35 project ventilation after the hazardous-area requirements are confirmed

Frequently asked questions

T35-11 / BT35-11 FAQ

What is the main difference between T35-11 and BT35-11?

T35-11 is used for general ventilation. BT35-11 enquiries require a project-specific review of the complete fan’s mechanical construction, electrical equipment and applicable certification, not only the motor.

Is an axial fan suitable for a long-duct system?

Usually not as the first choice. T35 and BT35 are mainly selected for large airflow and low resistance. Long ducts, filters and silencers may require a centrifugal fan.

Can BT35 be used in every hazardous area?

No. Explosion-proof grade, gas group, temperature class, certificate and installation method must match the specific hazardous-area requirement.

Can installation and voltage be customized?

Wall, duct and support-frame installation can be configured. Voltage and frequency can be matched to the project power supply.

What information should be sent for quotation?

Please provide airflow, pressure or duct resistance, installation method, medium, temperature, voltage, frequency, explosion-proof requirement, quantity and destination.

Send your T35 or BT35 ventilation requirements

Request a Project-Based Fan Selection

Send airflow, system resistance, installation method, medium condition, voltage and any explosion-proof requirement. The selected fan size, motor and configuration should be confirmed against the project operating point.