Steel Mill Wire Rod Air Cooling Axial Flow Fan

Project-oriented axial fan for controlled cooling sections in high-speed wire rod rolling lines, Stelmor-type conveyors and metallurgical air-cooling systems.

Multiple fans operate by cooling zone to provide high-volume airflow after wire rod laying, supporting coil temperature control, conveyor coordination and continuous rolling-line production.

Specialized Fan for Wire Rod Controlled Cooling

This axial flow fan is used below or alongside the air-cooling conveyor after wire rod laying. A fan bank supplies large-volume airflow through multiple cooling zones, helping regulate coil temperature and cooling intensity during continuous production.

The fan is intended for high-speed wire rod mills, Stelmor-type cooling conveyors and metallurgical controlled-cooling systems. It is not a general-purpose ventilation fan; selection must be coordinated with the rolling-line process, wire rod specification, conveyor arrangement and cooling target.

Final fan quantity, airflow distribution, pressure, motor configuration and control method should be confirmed from the complete cooling-line design rather than from a single reference working point.

Designed Around the Cooling Conveyor Process

Large Airflow Cooling

High-volume airflow removes heat from newly laid wire rod coils.

Multi-Zone Fan Control

Multiple fans regulate separate cooling zones along the conveyor.

Adjustable Airflow

0–100% airflow adjustment supports staged cooling requirements.

Rolling-Line Matching

Selection is coordinated with conveyor speed and line layout.

Continuous Duty Support

Built for stable cooling airflow during continuous steel production.

Project-Based Selection

Fan banks are selected from cooling load and airflow distribution.

Reference Configuration for One Cooling Section

The following figures are project reference data from the current page. Final selection must be recalculated according to wire rod grade and diameter, cooling rate, conveyor layout, ambient conditions and production capacity.

Item Reference Data
Application Wire rod air cooling section
Fan Quantity 8 sets for one air cooling section system
Air Volume 99,260 m³/h per fan
Pressure 248 kg/m², approximately 2,430 Pa
Airflow Adjustment 0–100%
Motor Power 90 kW per fan
Motor Type TETC AC motor, squirrel-cage type
Motor Speed 1,000 r/min
Voltage 380 V
Phase / Frequency 3 phase / 50 Hz

Fan Banks Work with the Conveyor Control Strategy

Fans are arranged along the cooling conveyor to create multiple controlled cooling zones. Airflow can be adjusted by zone according to wire rod specification, laying temperature, production speed and target cooling curve.

The fan system should be coordinated with roller conveyors, movable guide plates and line-speed control. Conveyor speed may remain consistent across the line or increase downstream according to material transfer and cooling requirements.

Information Required for Project Selection

Organize the request by the cooling process, the air path and the installation interface. Keep unknown values marked as pending rather than copying the reference configuration above.

1 · Production and cooling target

  • Steel grade and rod diameter range
  • Production capacity, line speed and conveyor speed
  • Rod inlet temperature, target cooling curve and measurement locations

2 · Zones and air distribution

  • Conveyor width, active length and cooling-zone layout
  • Required airflow per fan or zone, with the pressure basis identified
  • Plenums, ducts, dampers and outlet or nozzle arrangements
  • Fan-bank or centralized supply layout and intended zone control

3 · Installation or replacement evidence

  • Available dimensions, connections and installation constraints
  • Voltage, frequency, motor and control requirements
  • For a retrofit: existing nameplates, fan curves and control settings
  • Observed cooling variation and measurements taken at comparable production conditions

Fan quantity and duty points remain project-specific. A change in airflow alone does not establish the cooling result; the selected fan and air-distribution layout must be reviewed together.

Typical Steel Mill Applications

High-Speed Wire Rod Mill

Controlled cooling after high-speed wire rod laying.

Stelmor-Type Conveyor

Multi-zone airflow beneath the roller conveyor.

Steel Rolling Line

Cooling fan banks integrated into continuous rolling.

Metallurgical Cooling System

Process cooling requiring large, distributed airflow.

Controlled Cooling Process

Airflow adjusted to cooling curves and product grade.

Cooling Line Retrofit

Replacement or upgrade of existing fan-bank sections.

Related Products and Steel Mill Resources

Wire Rod Cooling Fan FAQ

Is this a general workshop ventilation fan?

No. It is a project-oriented axial fan designed for controlled cooling sections in wire rod rolling lines.

Why are multiple fans used in one cooling section?

A fan bank creates separate cooling zones so airflow can be adjusted along the conveyor according to the cooling process.

Can the reference 8-fan system be used for every project?

No. Fan quantity and duty points must be confirmed from cooling load, conveyor length, wire rod specification and production capacity.

What information is required before quotation?

Provide wire rod specification, production capacity, cooling target, conveyor layout, airflow, pressure, motor standard and site installation conditions.

Send Your Wire Rod Cooling Line Requirements

Send wire rod specification, cooling line layout, production capacity, airflow, pressure and motor requirements. QIYUE FAN will review a suitable fan-bank solution.

Hot Tags: steel mill wire rod air cooling axial flow fan, China steel mill wire rod air cooling axial flow fan manufacturers, suppliers, factory

Send Your Operating Conditions

Airflow, pressure, gas medium, temperature, voltage and quantity.